Back to Suppliers
|
Company name |
ellman
International. |
|
Origin |
USA. |
|
Line of Products |
High
Frequency Radiosurgical
Units. |
|
URL |
www.ellman.com |
Product Model
:
Surgitron Dual RF

The patented Surgitron Dual
Frequency unit represents advanced radiowave technology that provides
unparalleled surgical control, precision, versatility and safety.
The high frequency of 4.0MHz
minimizes heat dissipation and thus cellular alteration. Clinical
benefits include reduced post-operative discomfort, minimal scar tissue
formation, maximum readability of histologic specimen, enhanced healing
and excellent cosmetic results.
Ellmans technology has received
worldwide acclaim and recognition from leading surgeons, clinics,
universities and authors.
Features
-
Patented Technology reflecting over 40 years of innovation and
enhancement
-
Dual Frequency combining two optimal frequencies for maximum
surgical
-
benefits
-
Digital Operation for accurate parameter selection and viewing
-
Solid State Circuitry for dependable, consistent energy emission
-
Five Distinct Waveforms providing procedure / specific tissue
treatment
-
options
-
Monopolar and Bipolar Functions resulting in beyond-electrosurgery
control
-
and precision
-
120 Watt Output; maximum power needed for all surgical environments
-
Visual and Audible Safety Indicators to ensure maximum patient
safety
-
Parameter Recall allows rapid set-up for subsequent procedures
-
Multi-Specialty Applications; all medical disciplines benefit from
the
-
technology
-
Wide Delivery System Selection with constant expansion for emerging
medical
-
procedures
-
Ergonomic Design including simple menu format and low-profile design
which
-
permits ease of set-up and function by staff
Five Distinct Waveforms for Optimum Results
|
1. Fully Filtered - Cut |
|
 |
|
Micro-smooth
cutting
Negligible lateral heat
Minimal cellular destruction
Ideal for skin incision and biopsy.
Best cosmetic results. Fastest healing |
|
|
2. Fully Rectified - Cut/Coag |
|
 |
|
Cutting with
hemostasis
Ideal for sub-cutaneous tissue dissection and planing.
Especially useful in vascular
areas while producing minimal
amounts of lateral heat and tissue damage |
|
|
3. Partially Rectified - Coag |
|
 |
|
Coagulation /
Shrinkage
Ideal for cutting with hemostatic
control
Hemostasis with controlled
penetration |
|
|
4. Fulguration |
|
 |
|
Maximum penetration
and hemostasis
Ideal for intentional tissue destruction |
|
|
5. Bipolar |
|
-Pinpoint,
micro-coagulation
No tissue adherence to forceps
No charring or tissue necrosis
Ideal for coagulation in and around critical anatomy |
|
Specifications
|
Mode |
Output
Waveform |
Output
Frequency |
Maximum
Output Power |
|
Cut |
90% Cut
10% Coag |
4.0 MHz |
120W |
|
Cut/Coag |
50% Cut
50% Coag |
4.0 MHz |
90W |
|
Hemo |
10% Cut
90% Coag |
4.0 MHz |
60W |
|
Fulgurate |
Spark - Gap |
4.0 MHz |
45W |
|
Bipolar |
Same as Hemo |
1.7 MHz |
120W |
|
SIZE: 9W x 5H x 13
1/4D WEIGHT: 18 lbs. |